RP12 - RP13
M-1 active energy injection load curves, losses included, published per PADT, at a 10 minute step. Used to
follow injection in detail. A file carries one measurement installation, but its Corps blocks are all read.
Note
Only the RP12 file is read. An RP13 file is not recognised and is skipped.
Insights configuration
| Property | Value |
|---|---|
| Meter number of the source | Numero_PADT of the Corps block |
| Mapping config of the variable | See below |
| Granularity | The Granularite of the file, in minutes |
See Source configuration for the other properties.
Important
The meter number is the PADT number, not the PRM. A source created with the PRM of the installation never receives anything.
Mapping config
RP12_{Granularite}_{Statut_Point}
| Segment | Description | Values |
|---|---|---|
{Granularite} |
Granularity of the curve, in minutes, from the Granularite element |
5, 10, 15 |
{Statut_Point} |
Status of the measurement point, from the Statut_Point attribute |
R → REEL B → BRUT S → COUPURE E → ESTIME C → CORRIGE I → INVALIDE M → MANQUANT |
Points are grouped by status, so a file mixing statuses feeds one variable per status.
Examples
RP12_5_REEL
RP12_10_ESTIME
Tip
A key containing ??? means the file carried a status that is not part of the flow specification. No variable
will ever match it — report the file to support rather than creating a variable named after it.
Data point
| Timestamp | The Horodatage attribute of the point. Read as Europe/Paris when it carries no offset, stored in UTC — see Timestamps. |
| Value | The Valeur_Point attribute of the point |
What is not stored
- A point without
Valeur_Point— the attribute is absent when the measurement was not read, or when a correction has not been made yet.