Scroll down to learn more

Documentation Center

Welcome to Verity Documentation Center. You find here all the content you need to enjoy your data.

Search Results for

    Show / Hide Table of Contents

    R4C

    Load curve published for consumer and producer segments. R4C is the generic curve flow: it carries any type of measurement (energy, power, voltage) and any structure (index, volume, consumption, production), which is why its key is the longest of the family — every one of those dimensions becomes a segment.

    A file carries one PRM.

    Insights configuration

    Property Value
    Meter number of the source Id_PRM of the Corps block
    Mapping config of the variable See below

    See Source configuration for the other properties.

    Mapping config

    R4C_{Nature_De_Courbe_Demandee}_{Frequence_Publication}_{Reference_Publication}_{Sens_Mesure}_{Type_Mesure}_{Classe_Temporelle}_{Statut_Point}
    
    Segment Description Values
    {Nature_De_Courbe_Demandee} Type of curve requested Brute → BRUTE
    Corrigee → CORRIGEE
    {Frequence_Publication} Publication frequency, written as published Q: daily
    H: weekly
    M: monthly
    NA: element absent from the file
    {Reference_Publication} Publication reference, written as published Any value published
    NA: element absent from the file
    {Sens_Mesure} Direction of the measurement 0: consumption (soutirage)
    1: injection
    {Type_Mesure} Type of measurement, written as published PA: active power
    PR: reactive power
    {Classe_Temporelle} Time class, written as published See the Enedis flow documentation
    {Statut_Point} Status of the measurement point, from the Statut_Point element of the point R → RELEVE
    S → COUPURE
    E → ESTIME
    C → CORRIGE
    element absent → NA

    Points are grouped by status, so a curve mixing statuses feeds one variable per status.

    Important

    CORRIGEE and CORRIGE are two different segments. The curve is CORRIGEE, with the final E; the point status is CORRIGE, without it. A key ending in CORRIGEE never matches.

    Example

    R4C_CORRIGEE_M_NA_0_PA_BASE_CORRIGE
    

    Read as: corrected curve, monthly publication, no publication reference, consumption, active power, base time class, corrected points.

    Tip

    A key containing ??? means the file carried a value that is not part of the flow specification — an unknown curve nature or an unknown point status. No variable will ever match it. Report the file to support rather than creating a variable named after it.

    Data point

    Timestamp The H element of the point. Read as Europe/Paris when it carries no offset, stored in UTC — see Timestamps.
    Value The V element of the point

    What is not stored

    • A point without H or without V.
    DOCS 2026.08 Documentation changelog →

    Developer Center

    User manual API Swagger Github
    © 2025  -   www.verity.global