Scroll down to learn more

Documentation Center

Welcome to Verity Documentation Center. You find here all the content you need to enjoy your data.

Search Results for

    Show / Hide Table of Contents

    R10/R10A

    M-1 load curve of a C2 or C4 point, at 5 or 10 minute intervals. Used to follow customer consumption in detail. A file normally carries a single PRM, but every Corps it contains is read, so a file carrying several PRM feeds several sources.

    R10 and R10A are read by the same interpreter and produce the same keys.

    Insights configuration

    Property Value
    Meter number of the source Identifiant_PRM
    Mapping config of the variable See below
    Granularity 5 or 10 minutes, as published

    See Source configuration for the other properties.

    Mapping config

    R10_Classe-2_{Statut_Point}
    
    Segment Description Values
    Classe-2 Fixed. The flow carries measurements, never indexes. —
    {Statut_Point} Status of the measurement point, from the Statut_Point attribute R → RELEVE
    E → ESTIME
    C → CORRIGE

    Points are grouped by status, so a file mixing statuses feeds one variable per status.

    Note

    Any other status — including S, mains outage — is written as RELEVE. Those points land in the RELEVE variable together with the read ones.

    Example

    R10_Classe-2_ESTIME
    

    Data point

    Timestamp The Horodatage attribute of the point. No offset: read as Europe/Paris, stored in UTC — see Timestamps.
    Value The Valeur_Point attribute of the point

    What is not stored

    • A point without Horodatage, or without Valeur_Point — the attribute is absent when the measurement was not read, or when a correction has not been made yet.
    • A status whose points are all skipped produces no series at all, and therefore no warning about a missing variable.